Existing thermal pressure sensors generally have low sensitivity and low measurement accuracy.
Highly accurate barometric pressure sensors can be realized by applying SEMITEC’s thin-film thermistor FT.

Heating elements cool down due to changes in atmospheric pressure.
If the temperature of this heating element can be measured precisely, it can be used as a thermal barometric pressure sensor.
Thin- film sensor(FT series)

・Extremely small volume = small power for self-heating
Therefore, very sensitive to temperature changes
・Can produce two FT thermistors with nearly identical manufacturing characteristics
| SEMITEC Thermal Barometric Pressure Sensors | Example of a typical thermal conduction type sensor | |
|---|---|---|
| Principle | Thermal conduction type | Thermal conduction type |
| Output range | 240mV at100Pa | 4mV at100Pa |
| Permissible current | 30mA(Disconnection at 210mA) | 2mA(Disconnection at 10mA) |
| Pressure range | 0.15Pa~100,000Pa | 0.4Pa~3,000Pa |
| Operating temperature range | 0℃~40℃ | 10℃~50℃ |
| Tolerance | ±1%(6σ) | ±15% |
| Reproducibility | ±1.4% at100Pa (Constant environmental temperature) |
±15% (Constant environmental temperature) |
| Stability time | 1min | 20min |
| Pressure resistant | 0.2MPa | 0.2MPa |